Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 655
Filter
1.
RFO UPF ; 29(1)20240000.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1537721

ABSTRACT

Objetivo: Determinar as evidências científicas sobre a influência do uso de lasers de baixa e alta intensidade no tratamento da hipersensibilidade da dentina. Revisão de literatura: Foram realizadas buscas na Biblioteca Virtual em Saúde (BVS), incluindo as bases de dados: Literatura Latino Americana e do Caribe em Ciências da Saúde (LILACS); Bibliografia Brasileira de Odontologia (BBO); e National Library of Medicine (MEDLINE). A maioria dos estudos destacam a eficácia dos lasers na redução da HD, com o laser Nd:YAG mostrando-se eficaz na obliteração dos túbulos dentinários e proporcionando alívio a longo prazo. Apesar dos benefícios, alguns estudos alertam para possíveis danos à polpa dentária, especialmente com lasers de alta potência. Considerações finais: Embora os lasers tenham se mostrado eficazes na redução da HD, a escolha do laser deve ser personalizada para cada paciente, destacando a necessidade de aprimorar os protocolos clínicos e adquirir experiência relevante por parte dos profissionais especialistas.


Objective: To determine the scientific evidence on the influence of the use of low and high intensity lasers in the treatment of dentin hypersensitivity. Literature review: Searches were carried out in the Virtual Health Library (VHL), including the databases: Latin American and Caribbean Literature in Health Sciences (LILACS); Brazilian Bibliography of Dentistry (BBO); and National Library of Medicine (MEDLINE). Most studies highlight the effectiveness of lasers in reducing HD, with the Nd:YAG laser proving effective in obliterating dentinal tubules and providing long-term relief. Despite the benefits, some studies warn of possible damage to the dental pulp, especially with high-power lasers. Final considerations: Although lasers have been shown to be effective in reducing HD, the choice of laser must be personalized for each patient, highlighting the need to improve clinical protocols and acquire relevant experience on the part of specialist professionals.

2.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520241

ABSTRACT

ABSTRACT Purpose: This study aimed to report an experiment designed to determine anatomical changes in porcine corneas following placement of a novel polymer implant into the cornea. Methods: An ex vivo porcine eye model was used. A novel type I collagen-based vitrigel implant (6 mm in diameter) was shaped with an excimer laser on the posterior surface to create three planoconcave shapes. Implants were inserted into a manually dissected stromal pocket at a depth of approximately 200 μm. Three treatment groups were defined: group A (n=3), maximal ablation depth 70 μm; Group B (n=3), maximal ablation depth 64 μm; and group C (n=3), maximal ablation depth 104 μm, with a central hole. A control group (D, n=3) was included, in which a stromal pocket was created but biomaterial was not inserted. Eyes were evaluated by optical coherence tomography (OCT) and corneal tomography. Results: Corneal tomography showed a trend for a decreased mean keratometry in all four groups. Optical coherence tomography showed corneas with implants placed within the anterior stroma and visible flattening, whereas the corneas in the control group did not qualitatively change shape. Conclusions: The novel planoconcave biomaterial implant described herein could reshape the cornea in an ex vivo model, resulting in the flattening of the cornea. Further studies are needed using in vivo animal models to confirm such findings.


RESUMO Objetivo: Relatar um experimento projetado para determinar alterações anatômicas em córneas porcinas após a colocação de um novo implante de polímero na córnea. Métodos: Foi utilizado olho de porco ex vivo. Um novo agente modelador biocompatível, de colágeno tipo 1, com 6mm de diâmetro foi moldado com excimer laser em sua face posterior, para criar três formatos planocôncavos. Os implantes foram inseridos dentro de um bolsão, dissecado manualmente, a 200 micrômetros (μm). Foram definidos três grupos de tratamento: grupo A (n=3), teve a profundidade máxima de ablação de 70 μm; o grupo B (n=3), profundidade máxima de ablação de 64 μm; e o grupo C (n=3), profundidade máxima de ablação de 104 μm, com buraco central. O grupo controle, D (n=3), foi incluído, com a criação do bolsão estromal, porém sem inserir o material. A avaliação desses olhos foi realizada por tomografia de coerência óptica (OCT) e por tomografia corneana. Resultados: A tomografia corneana mostrou uma tendência para diminuição da ceratometria média em todos os 4 grupos. A tomografia de coerência óptica mostrou córneas com implantes localizados no estroma anterior e aplanamento visível, enquanto as córneas não mudaram qualitativamente o formato no grupo controle. Conclusões: O novo implante de biomaterial planocôncavo descrito aqui foi capaz de remodelar a córnea em modelo de animal ex vivo, resultando no aplanamento corneano. Novos estudos são necessários usando modelos animais in vivo para confirmar tais achados.

3.
Arq. bras. oftalmol ; 87(2): e2021, 2024.
Article in English | LILACS-Express | LILACS | ID: biblio-1527835

ABSTRACT

ABSTRACT Purpose: This study aimed to evaluate the long-term safety and efficacy of neodymium-doped yttrium aluminum garnet (Nd:YAG) vitreolysis for symptomatic vitreous floaters as it remains a controversial procedure due to insufficient robust evidence in the literature for the maintenance of the results and absence of adverse effects. Methods: This is an observational extension to the previously presented prospective, randomized, double-blind clinical trial. Eight of thirteen subjects who underwent vitreolysis with YAG laser returned for a late reevaluation, 18 months after the procedure, to evaluate the efficacy and safety of the procedure. Results: All patients maintained the improvement in symptomatology noted after the procedure, with 25% showing complete improvement and a similar proportion (37.5%) reporting significant or partial improvement. Objective improvement in opacity was similar to that found at 6 months follow-up. The NEI-VFQ 25 quality of life questionnaire showed no statistically significant difference in responses between the 6th and 18th month. No adverse effects were noted on clinical examination or reported by patients. Conclusion: Vitreolysis efficacy observed at 6 months of follow-up was maintained until the eighteenth month, with all patients reporting improvement from the pre-procedure state. No late adverse effects were noted. A larger randomized clinical trial is needed to confirm the safety of the procedure.


RESUMO Objetivos: Avaliar a segurança e eficácia a longo prazo da vitreólise com Nd:YAG laser para moscas volantes sintomáticas, uma vez que permanece como um procedimento controverso devido a falta de evidência científica robusta sobre a manutenção dos resultados e ocorrência de efeitos adversos. Métodos: Este estudo é uma extensão observacional de um ensaio clínico prospectivo, randomizado, duplo cego, previamente publicado. Oito de treze pacientes que foram submetidos a vitreólise com YAG laser foram acompanhados para uma reavaliação tardia, dezoito meses após o procedimento, para avaliar a eficácia e segurança do procedimento. Resultados: Todos os pacientes mantiveram a melhora na sintomatologia notada ao final do procedimento original, com 25% dos casos apresentando melhora completa, e uma proporção semelhante (37,5%) demonstrando melhora significativa ou parcial. A melhora objetiva na opacidade foi similar ao achado no seguimento original de 6 meses. O questionário de qualidade de vida NEI-VFQ 25 não demonstrou diferença estatisticamente significativa nas respostas entre o sexto e o décimo oitavo mês de acompanhamento. Nenhum efeito adverso foi notado no exame clínico ou reportado pelos pacientes. Conclusão: A eficácia da vitreólise observada ao sexto mês do acompanhamento foi mantida até o décimo oitavo mês, com todos os pacientes notando algum grau de melhora quando comparado ao estado pré procedimento. Nenhum efeito adverso tardio foi notado. Um ensaio clínico randomizado maior é necessário para confirmar a segurança do procedimento.

4.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527854

ABSTRACT

ABSTRACT Purpose: This study aimed to compare an teriorchamber parameters acquired by a swept-source anteriorsegment optical coherence tomography before and after laser peripheral iridotomy. Methods: This study prospectively evaluated 14 patients with primary-angle closure and six patients with primary-angle closure glaucoma. Gonioscopy and anterior-segment optical coherence tomography using the DRI OCT Triton® were performed before and after laser peripheral iridotomy. Anterior-segment optical coherence tomography parameters were studied using scleral spur as reference: angle opening distance at 250, 500, and 750 µm, trabecular-iris space at 500 µm, trabecular-iris angle, trabecular-iris contact length, and iris curvature. Results: Anterior-segment optical coherence tomography identified 61% of the patients with two or more quadrants closed. Gonioscopy identified more closed angles than anterior-segment optical coherence tomography before laser peripheral iridotomy. In angle parameters, only the angle opening distance of 250 µm at the nasal quadrant was not significantly increased after laser peripheral iridotomy. The iris curvature and trabecular-iris contact length showed a significant reduction induced by the laser procedure. Even in eyes in which gonioscopy did not identify angular widening after laser peripheral iridotomy (n=7), the angle opening distance of 750 µm increased (nasal, 0.15 ± 0.10 mm to 0.27 ± 0.16 mm, p=0.01; temporal, 0.14 ± 0.11 mm to 0.25 ± 0.12 mm, p=0.001) and the iris curvature decreased (nasal, 0.25 ± 0.04 mm vs. 0.11 ± 0.07 mm, p=0.02; temporal, 0.25 ± 0.07 mm vs. 0.14 ± 0.08 mm, p=0.007). Conclusions: Anterior-chamber changes induced by laser peripheral iridotomy could be quantitatively evaluated and documented by DRI OCT Triton®


RESUMO Objetivo: Comparar os parâmetros de câmara anterior obtidos através da tomografia de coerência óptica de segmento anterior antes e após a iridectomia periférica a laser. Métodos: Quatorze pacientes com fechamento angular primário e seis com glaucoma primário de ângulo fechado foram prospectivamente avaliados neste estudo. Gonioscopia e tomografia de coerência óptica de segmento anterior com DRI OCT Triton® foram realizadas antes e após a iridectomia periférica a laser. Os seguintes parâmetros de tomografia de coerência óptica de segmento anterior, baseados na localização do esporão escleral, foram avaliados: ângulo de abertura angular a 250 µm, 500 µm e 750 µm, área do espaço entre a íris e o trabeculado a 500 µm, ângulo entre a íris e o trabeculado, extensão do contato entre a íris e o trabeculado e curvatura da íris. Resultados: A tomografia de coerência óptica de segmento anterior identificou 61% dos indivíduos com dois ou mais quadrantes fechados. A gonioscopia identificou mais quadrantes com ângulo fechado do que tomografia de coerência óptica de segmento anterior antes da iridectomia periférica a laser. Quanto aos parâmetros angulares, apenas ângulo de abertura angular a 250 µm no quadrante nasal não aumentou significativamente após a iridectomia periférica a laser. A curvatura da íris e a extensão do contato entre a íris e o trabeculado apresentaram redução significativa induzida pelo procedimento a laser. Mesmo nos olhos em que a gonioscopia não identificou aumento da amplitude angular após iridectomia periférica a laser (n=7), ângulo de abertura angular a 750 µm aumentou (nasal: 0,15 ± 0,10 mm para 0,27 ± 0,16 mm, p=0,01; temporal: 0,14 ± 0,11 mm para 0,25 ± 0,12 mm, p=0,001), e ICURVE diminuiu (nasal: 0,25 ± 0,04 mm vs. 0,11 ± 0,07 mm, p=0,02; temporal: 0,25 ± 0,07 mm vs. 0,14 ± 0,08 mm, p=0,007). Conclusões: As alterações na câmara anterior induzidas pelo iridectomia periférica a laser puderam ser avaliadas quantitativamente e documentadas pelo DRI OCT Triton®.

5.
Int. braz. j. urol ; 49(5): 608-618, Sep.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1506422

ABSTRACT

ABSTRACT Introduction: The aim of the study was to investigate clinical and surgical factors associated with early catheter replacement in patients treated with Holmium Laser Enucleation of the Prostate (HoLEP). Materials and Methods: Data of patients treated with HoLEP at our Institution by a single surgeon from March 2017 to January 2021 were collected. Preoperative variables, including non-invasive uroflowmetry and abdominal ultrasonography (US), were recorded. Bladder wall modifications (BWM) at preoperative US were defined as the presence of single or multiple bladder diverticula or bladder wall thickening ≥5 mm. Clinical symptoms were assessed using validated questionnaires. Only events occurred within the first week after catheter removal were considered. Results: Overall, 305 patients were included, of which 46 (15.1%) experienced early catheter replacement. Maintenance of anticoagulants/antiplatelets (AC/AP) therapy at surgery (p=0.001), indwelling urinary catheter (p=0.02) and the presence of BWM (p=0.001) were more frequently reported in patients needing postoperative re-catheterization. Intraoperative complications (p=0.02) and median lasing time (p=0.02) were significantly higher in this group. At univariate analysis, indwelling urinary catheter (p=0.02), BWM (p=0.01), ongoing AC/AP therapy (p=0.01) and intraoperative complications (p=0.01) were significantly associated with early catheter replacement. At multivariate analysis, indwelling urinary catheter (OR: 1.28; p=0.02), BWM (OR: 2.87; p=0.001), and AC/AP therapy (OR: 2.21; p=0.01) were confirmed as independent predictors of catheter replacement. Conclusions: In our experience the presence of indwelling urinary catheter before surgery, BWM and the maintenance of AC/AP therapy were shown to be independent predictors of early catheter replacement after HoLEP.

6.
Biomédica (Bogotá) ; 43(3): 315-322, sept. 2023. graf
Article in English | LILACS | ID: biblio-1533942

ABSTRACT

Introduction. Over time, efforts have been invested in the design of new instruments that overcome the disadvantages of the gold standard instrument in surgery, the scalpel. As a result, electronic equipment has emerged such as the electric scalpel and laser devices. The available evidence on these instruments suggests that the tissue response is related to each instrument's physical and biological cutting principles. Objective. To compare the histological changes in gingiva samples associated with surgical cutting performed with a 940 nm diode laser, a 2780 nm erbium, chromium: yttriumscandium-gallium-garnet (Er,Cr:YSGG) laser, and an electric scalpel, by presenting a series of cases. Case presentation. We present three cases of healthy patients undergoing cosmetic surgery. The clinical examination revealed exposure of a keratinized gingiva band greater than 4 mm, normal color and texture in gingival tissue, with a firm consistency and no bleeding on periodontal probing. Gingivectomy was indicated with the following protocols: Diode laser of 940 nm at 1 W, in continuous mode; Er,Cr:YSGG laser of 2780 nm at 2.5 W, 75 Hz, H mode, air 20, water 40, gold tip MT4); and electric scalpel in cutting mode at power level four. Gingival tissue samples were taken and stored in 10% formaldehyde for histological analysis. Conclusion. All the evaluated cutting instruments generated histological changes produced by the thermal effect, the main ones being collagen coagulation and carbonization. The depth of thermal damage caused by the 2780 nm Er,Cr:YSGG laser was much lesser than that induced by the electric scalpel and the 940 nm diode laser.


Introducción. Históricamente se ha invertido esfuerzo en el diseño de nuevos instrumentos que superen las desventajas del estándar de referencia en cirugía, el bisturí. Como consecuencia de esto, han surgido equipos electrónicos como el electrobisturí y los diferentes dispositivos de tecnología láser. La información disponible sobre estos instrumentos sugiere que la respuesta del tejido intervenido está influenciada por los principios físicos y biológicos de corte del instrumento. Objetivo. Comparar los cambios histológicos en muestras de encía asociados al corte quirúrgico realizado con láser de diodo de 940 nm, láser de erbio, cromo: itrio-escandio-galio-granate (Er,Cr:YSGG) (2780nm) y electrobisturí mediante una presentación de serie de casos. Presentación de los casos. Se presentan tres casos de pacientes sanos sometidos a cirugía estética. El examen clínico reveló la exposición de una banda gingival queratinizada mayor de 4 mm, tejido gingival de color y textura normales, de consistencia firme y sin sangrado al sondaje periodontal. Se indicó gingivectomía con los siguientes protocolos: láser de diodo de 940 nm a 1 W, en modo continuo; láser de Er,Cr:YSGG de 2780 nm a 2,5 W, 75 Hz, modo H, aire 20, agua 40, punta de oro MT4; y bisturí eléctrico en modo de corte, a nivel de potencia cuatro. Se tomaron muestras de tejido gingival y se almacenaron en formaldehído al 10 % para su análisis histológico. Conclusión. Los tres instrumentos de corte generaron cambios histológicos producidos por el efecto térmico; los principales fueron coagulación del colágeno y carbonización. La profundización del daño térmico causada por el láser de Er,Cr:YSGG de 2780 nm fue mucho menor que la generada por el electrobisturí y por el láser de diodo de 940 nm.


Subject(s)
Gingivectomy , Artifacts , Lasers, Semiconductor , Lasers, Solid-State , Histology
7.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3210-3218
Article | IMSEAR | ID: sea-225263

ABSTRACT

Purpose: Compare the safety and efficacy of wavefront?guided photorefractive keratotomy (PRK) 6 months after cross?linking (CXL) to wavefront?guided PRK alone for refractive correction in patients with bilateral asymmetric corneal topography. Methods: Prospective randomized clinical trial with 16 patients (32 eyes). CXL with subsequent PRK after 6 months in one eye, and PRK alone was performed in contralateral eyes. The follow?up was 10 years. We analyzed visual outcomes, Scheimpflug topography, and corneal haze evaluation. Results: Eyes in the PRK group showed better results than in the CXL + PRK group. Mean postoperative CDVA was 0.044 logmar (SD, 0.073) in the PRK group and 0.1 logmar (SD, 0.21) in the CXL + PRK group, the mean sphere was + 0.21 (SD, 0.6) D in the PRK group and 0.87 (SD, 2.3) D in the CXL + PRK group, and mean SE was ?0.35 (SD, 0.65) D in the PRK group and 0.62 (SD, 2.32) D in the CXL + PRK group. In one patient, a steepening of 2.5 D and a thinning of 17 ?m occurred in PRK alone group. Two patients in the CXL + PRK group presented corneal haze. The overall complication rate was 18,75% (haze and ectasia). Conclusion: Non?simultaneous CXL and PRK procedures yielded good refractive results, but worse than those obtained with PRK alone. Although one patient in the PRK group developed corneal ectasia, the CXL + PRK group had a higher loss of vision lines, indicating less safety

8.
Rev. ADM ; 80(4): 190-196, jul.-ago. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1525858

ABSTRACT

Introducción: la adaptación marginal e interna de nuestras restauraciones fabricadas por fundición sistemas de fresado y sinterización láser es uno de los factores clínicos más importantes para el éxito de las prótesis fijas, previniendo el riesgo de microfiltración y enfermedad periodontal. Objetivo: evaluar la adaptación marginal e interna de cofias metálicas en aleación Cr-Co confeccionadas por técnicas convencionales, CAD/ CAM de fresado y sinterizado por láser. Material y métodos: estudio de tipo experimental, comparativo e in vitro. Se imprimió un modelo maestro en Cr-Co, proveniente del escaneo de un premolar preparado para corona completa, sobre el cual se diseñaron 30 cofias divididas en tres grupos: el primero que corresponde al grupo cofias fundidas fresadas en disco de cera A (A = 10), el segundo grupo cofias fresadas en disco de metal presinterizado B (B = 10) y el tercer grupo cofias impresas por sinterización láser C (C = 10). Se empleó la réplica de silicona, colocando silicona al interior de cada cofia, sobre el modelo maestro, simulando al cemento, mediante una máquina de ensayo universal se realizó una compresión de 50 N. Luego de retirar cada cofia se rellenaron con silicona pesada de adición, obteniendo una réplica de silicona. Se efectuaron dos cortes transversales en sentido vestíbulolingual y mesiodistal. Se observó el espesor de silicona VPS (vinil poliéter silicona) mediante un estereomicroscopio (Nikon SMZ745T), obteniendo valores en micrómetros. Para el análisis estadístico se utilizó el software SPSS 25 con el fin de realizar la prueba de normalidad y ANOVA de dos vías bajo un nivel de confianza del 95%. Resultados: el menor gap lo obtuvo el grupo de fresadas, seguido de las impresas y por último las fundidas por métodos convencionales. ANOVA de dos vías reveló diferencias estadísticamente significativas entre los tres grupos (p < 0.0001). Conclusiones: se encontró que el gap varía con cada método de fabricación, la técnica convencional de fundido mostró un mayor gap, ninguna excediendo el rango clínicamente aceptable (AU)


Introduction: the marginal and internal adaptation of our restorations manufactured by casting, milling systems and laser sintering is one of the most important clinical factors for the success of fixed prostheses, preventing the risk of microleakage and periodontal disease. Objective: evaluate the marginal and internal adaptation of metal copings in Cr-Co alloy made by conventional techniques, CAD/CAM milling and laser sintering. Material and methods: an experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown. An experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown, on which 30 caps divided into three groups were designed; the first group corresponds to the cast copings milled on a wax disc A (A = 10), the second group milled copings on a presintered metal disc B (B = 10) and the third group printed by laser sintering copings C (C = 10). The silicone replica was used, placing silicone inside each coping, on the master model, simulating cement, using a universal testing machine, a 50 N compression was performed. After removing each coping, they were filled with heavy addition silicone, obtaining a silicone replica. Two cross-sections were made in the buccolingual and mesiodistal direction., observing the thickness of the VPS (vinyl polyeter silicone) silicone using a stereomicroscope (Nikon SMZ745T), obtaining values in micrometers. For the statistical analysis, the SPSS 25 software was used in order to perform the normality and two-way ANOVA tests under a 95% confidence level. Results: the smallest gap was obtained by the milled group, followed by the printed ones and finally those cast by conventional methods. Two-way ANOVA revealed statistically significant differences between the three groups (p < 0.0001). Conclusions: the gap was found to vary with each fabrication method, the conventional casting technique showed a larger gap, none exceeding the clinically acceptable range (AU)


Subject(s)
Chromium Alloys , Computer-Aided Design , Dental Marginal Adaptation , Crowns , Lasers , In Vitro Techniques , Analysis of Variance
9.
Int. braz. j. urol ; 49(4): 501-510, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1506396

ABSTRACT

ABSTRACT Objective: To describe the technique of transurethral harvesting of bladder mucosal graft using the Holmium:YAG (Ho-YAG) laser and describe the preliminary results from 7 cases where this graft was used for urethroplasty. Materials and Methods: We performed a single-stage dorsal onlay urethroplasty using bladder mucosal graft in 7 patients with anterior urethral stricture. Transurethral harvesting was performed with the Ho-YAG laser. We performed a prospective and descriptive analysis with uroflowmetry performed at 30, 90 and 180 days after surgery and applied the PROM translated into Portuguese before and 6 months after urethroplasty. Results: Seven patients were included, 2 (28.5%) with penile urethral stricture, and 5 (71.5%) with bulbar urethral stricture. Mean stricture length was 50mm (range 35-60mm). Stricture etiology was trauma in 3 (42.9%) patients, iatrogenic in 1 (14.3%) patient, and idiopathic in 3 (42.9%) patients. Two patients (28.6%) had previously undergone ventral buccal mucosa urethroplasty. Mean bladder mucosal graft length was 52.86mm (± 13.801), and mean harvest time was 46.43min (± 14.639). Dorsal onlay urethroplasty using bladder mucosa was successfully completed in 5 patients (71.4%). Two patients (28.6%) couldn't have the procedure completed using bladder mucosa, one due to thermal damage of the graft during harvesting, and one due to insufficient graft length. In both cases the procedure was completed using buccal mucosa. Two patients (28.6%) experienced minor hematuria between the twelfth and eighteenth postoperative day, but neither required hospitalization and/or additional procedures. All patients achieved normalization of peak flow, and this was maintained throughout the follow-up period. Mean peak flow was 17.8 ml/s (± 3.271) at 30 days, 20.6 ml/s (± 5.413) at 90 days, and 19.6 ml/s (± 8.019) 180 days. Mean IPSS score decreased from 19.3 to 5.4. Similar improvements were also seen in the ICIQ-MLUTS Score (a mean drop from 3.8 to 2.0) and Peeling's Voiding Picture Score (a mean drop from 4.0 to 2.2). Quality of Life improved post urethroplasty, with increases in EQ-5D (from 0.6371 to 0.7285) and EQ-VAS (from 58.0 to 84.0). Conclusion: Transurethral harvesting of bladder mucosa using the Holmium laser (Ho-YAG) is feasible and reproducible. Our preliminary experience suggests that bladder mucosa grafts achieve comparable results to other grafts when used for dorsal onlay urethroplasty. Further research is needed to confirm these results.

10.
Int. braz. j. urol ; 49(3): 341-350, may-June 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1440252

ABSTRACT

ABSTRACT Introduction We assessed the efficacy and safety of holmium laser enucleation of the prostate (HoLEP) in patients with high comorbidity burden. Materials and methods Data from patients treated with HoLEP at our academic referral center from March 2017 to January 2021 were prospectively collected. Patients were divided according to their CCI (Charlson Comorbidity Index). Perioperative surgical data and 3-month functional outcomes were collected. Results Out of 305 patients included, 107 (35.1%) and 198 (64.9%) were classified as CCI ≥ 3 and < 3, respectively. The groups were comparable in terms of baseline prostate size, symptoms severity, post-void residue and Qmax. The amount of energy delivered during HoLEP (141.3 vs. 118.0 KJ, p=0.01) and lasing time (38 vs 31 minutes, p=0.01) were significantly higher in patients with CCI ≥ 3. However, median enucleation, morcellation and overall surgical time were comparable between the two groups (all p>0.05). Intraoperative complications rate (9.3% vs. 9.5%, p=0.77), median time to catheter removal and hospital stay were comparable between the two cohorts. Similarly, early (30 days) and delayed (>30 days) surgical complications rates were not significantly different between the two groups. At 3-month follow up, functional outcomes using validated questionnaires did not differ between the two groups (all p>0.05). Conclusions HoLEP represents a safe and effective treatment option for BPH also in patients with high comorbidity burden.

11.
Article | IMSEAR | ID: sea-218502

ABSTRACT

Introduction: The available data regarding scalpel and diode laser incisions wound healing is variable, scarce and needs more clarification especially in normal healthy tissues. Hence, this study was aimed to evaluate clinical and histologic parameters of wound healing with scalpel and diode laser on oral mucosa of Guinea pigs. Materials and Methods: This is an experimental study conducted on four male Guinea pigs. Laser and scalpel incisions were made on the right buccal mucosa of each guinea pig approximately 5mm deep and 10 mm in length and both the incisions were placed 10 mm apart using No#11Bard Parker blades and diode laser (640 wavelength) under general anesthesia. Punch biopsies of both the incisions were obtained and compared for clinical changes such as ease of working, intra-operative bleeding, color and approximation of wound edges and histological changes such as epithelial proliferation, inflammation, angiogenesis, and fibrosis on day 1, 3 and 7. Results: Clinically, scalpel wounds showed better healing than laser wounds although laser incisions provided bloodless surgical field. There was no significant difference in inflammation, angiogenesis and fibrosis between scalpel and diode laser incisions on both day 3 and 7 except for the epithelization which was comparatively early and better in scalpel wounds than the diode laser wounds. Conclusion: Diode lasers provide bloodless surgical field with better visibility than scalpel without any difference in oral mucosal wound healing. Considering the clinical benefits, the diode lasers could be a superior alternative to conventional scalpel technique.

12.
J. oral res. (Impresa) ; 12(1): 86-99, abr. 4, 2023. ilus
Article in English | LILACS | ID: biblio-1512278

ABSTRACT

Objective: The objective of this study was to investigate the morphology, proliferation, and differentiation of gingival mesenchymal stem cells (GMSCs) irradiated with a 970 nm Diode Laser (LLLT). It is essential to validate the efficacy of treatment, optimize irradiation conditions and guarantee the safety and quality of stem cells for future use in dental applications. Materials and Methods: GMSCs were cultured in standard conditions and irradiated with a Diode laser (970 nm, 0.5W) with an energy density of 9J/cm2. Cell proliferation was assessed with the WST-1 proliferation kit. GMSCs were differentiated into chondrogenic and osteogenic lineages. Cell morphology was performed with Hematoxylin/eosin staining, and quantitative nuclear analysis was done. Cell viability was monitored with trypan blue testing. Results: GMSCs subjected to irradiation demonstrated a significant increase in proliferation at 72 hours compared to the non-irradiated controls (p=0.027). This indicates that the 970 nm diode laser has a stimulatory effect on the proliferation of GMSCs. LLLT-stimulated GMSCs exhibited the ability to differentiate into chondrogenic and osteogenic lineages. A substantial decrease in cell viability was observed 24 hours after irradiation (p=0.024). However, after 48 hours, the cell viability recovered without any significant differences. This indicates that there might be a temporary negative impact on cell viability immediately following irradiation, but the cells were able to recover and regain their viability over time. Conclusions: This study support that irradiation with a 970 nm diode laser could stimulate the proliferation of GMSCs, maintain their ability to differentiate into chondrogenic and osteogenic lineages, and has minimal impact on the mor- phological characteristics of the cells. These results support the potential use of NIR Lasers in combination with GMSCs as a promising strategy for dental treatments.


Objetivo: El objetivo de este estudio fue investigar la morfología, proliferación y diferenciación de las células madre mesenquimatosas (GMSC) irradiadas con un láser de diodo de 970 nm (LLLT). Es fundamental validar la eficacia del tratamiento, optimizar las condiciones de irradiación y garantizar la seguridad y calidad de las células madre para su uso futuro en aplicaciones dentales.Materiales y Métodos: Las GMSC se cultivaron en condiciones estándar y se irradiaron con un láser de diodo (970 nm, 0,5 W) con una densidad de energía de 9 J/cm2. La proliferación celular se evaluó con el kit de proliferación WST-1. Las GMSC se diferenciaron en linajes condrogénicos y osteogénicos. La morfología celular se realizó con tinción de hematoxilina/eosina y se realizó un análisis nuclear cuantitativo. La viabilidad celular se controló con prueba de azul de tripano. Resultados: Las GMSC sometidas a irradiación demostraron un aumento significativo en la proliferación a las 72 horas en comparación con los controles no irradiados (p=0,027). Esto indica que el láser de diodo de 970 nm tiene un efecto estimulante sobre la proliferación de GMSC. Las GMSC estimuladas con LLLT exhibieron la capacidad de diferenciarse en linajes condrogénicos y osteogénicos. Se observó una disminución sustancial de la viabilidad celular 24 horas después de la irradiación (p=0,024). Sin embargo, después de 48 horas, la viabilidad celular se recuperó sin diferencias significativas. Esto indica que podría haber un impacto negativo temporal en la viabilidad de las células inmediatamente después de la irradiación, pero las células pudieron recuperarse y recuperar su viabilidad con el tiempo. Conclusión: En conclusión, este estudio respalda que la irradiación con un láser de diodo de 970 nm podría estimular la proliferación de GMSC, mantener su capacidad para diferenciarse en linajes condrogénicos y osteogénicos y tiene un impacto mínimo en las características morfológicas de las células. Estos resultados respaldan el uso potencial de láseres NIR en combinación con GMSC como una estrategia prometedora para tratamientos dentales.


Subject(s)
Humans , Low-Level Light Therapy , Cell Proliferation/radiation effects , Lasers, Semiconductor , Mesenchymal Stem Cells/radiation effects , In Vitro Techniques , Gingiva/radiation effects
13.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 69(12): e20230740, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1521498

ABSTRACT

SUMMARY OBJECTIVE: We investigated the effectiveness of combining laser treatment with phenol in the management of pilonidal sinus. METHODS: We present here a retrospective analysis of patients with pilonidal sinus disease who were treated in the general surgery clinic of the Balikesir University Hospital between October 2019 and February 2022. RESULTS: Recurrence was observed in three patients (13.6%) in the laser treatment group and one patient (4.8%) in the laser-phenol treatment group after the fourth month. Notably, 22 (91.7%) patients in the laser treatment group and 21 (95.5%) patients in the laser-phenol treatment group had complete healing. CONCLUSION: Although not statistically significant, the laser-phenol treatment group exhibited a lower recurrence rate and a higher complete healing rate.

14.
Acta cir. bras ; 38: e386023, 2023. graf, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1527584

ABSTRACT

Purpose: After partial hepatectomy (PH), the remaining liver (RL) undergoes regenerative response proportional to the host. Limited literature exists on hepatic viability after tissue injury during hypothermic preservation. Spectroscopy measures cellular fluorescence and is explored for tissue characterization and parameter investigation. This study aimed to assess fluorescence analysis (spectroscopy) in evaluating liver viability and its relationship with hepatic tissue regeneration 24 hours after PH. Additionally, we analyzed liver regeneration in RL after 70% partial hepatectomy under hypothermic conditions with laser irradiation. Methods: Fifty-six Wistar rats were divided into four groups: total non-perfused liver (control), total perfused liver, partial hepatectomy "in situ", and partial hepatectomy "ex situ". Tissue analysis was performed at 0 and 24 hours using spectroscopy with laser devices emitting at 532 (green) and 405 nm (violet). Results: Spectroscopy identified tissue viability based on consistent results with Ki67 staining. The fluorescence spectra and Ki67 analysis displayed similar patterns, linking proliferative activity and absorption intensity. Conclusions: Fluorescence spectroscopy proves to be promising for real-time analysis of cellular activity and viability. Metabolic activity was observed in groups of live animals and hypothermically preserved samples, indicating cellular function even under blood deprivation and hypothermic conditions.


Subject(s)
Animals , Rats , Spectrometry, Fluorescence , Ischemia , Lasers , Liver/injuries
15.
Rev. bras. oftalmol ; 82: e0021, 2023. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1441325

ABSTRACT

RESUMO O FemtoLasik é uma das técnicas mais empregadas em cirurgia refrativa, por seus bons resultados refracionais, sua previsibilidade, sua reprodutibilidade e sua segurança. Tem alto grau de satisfação, com rápida recuperação visual. Apesar de as taxas de complicações do FemtoLasik serem pequenas, intercorrências podem existir. O objetivo deste trabalho foi relatar um caso de uma complicação na dissecção da lamela por Lasik com laser de femtossegundo com consequente rasgadura da lamela, sendo aplicado Excimer Laser com mitomicina C 0,02%. O retratamento foi realizado com ablação de superfície (ceratectomia fotorrefrativa) guiada por frente de onda, evoluindo com boa qualidade visual final.


ABSTRACT Femtolasik is one of the most used techniques in refractive surgery due to good refractive results, predictability, reproducibility, and safety, achieving excellent results and a high degree of satisfaction. Although the complication rates are small, it is worth noting that there may be intercurrences. The objective of this work is to report a case of complication in the dissection of the lamella of laser in situ keratomileusis (Lasik) with Femtosecond laser, and subsequent lamella tear. Excimer Laser was applied with mitomycin 0.02% and re-approached with wavefront guided surgery, evolving with good final visual quality.

16.
Pesqui. bras. odontopediatria clín. integr ; 23: e220144, 2023. tab, graf
Article in English | LILACS, BBO | ID: biblio-1529118

ABSTRACT

ABSTRACT Objective: To compare and evaluate the clinical efficacy of diode laser and cryosurgery for treating melanin pigmentation of gingiva. Material and Methods: A total of twenty-five subjects with physiological gingival pigmentation on the facial aspect of both maxillary and mandibular anterior arches (50 sites), both male and female, with an average age ranging from 18-35 years, participated in the study. The sites were randomly divided into Group I: depigmentation by Laser and Group II: depigmentation by Cryosurgery. The following parameters were assessed for the evaluation of treatment results: Melanin Oral Pigmentation Index (PI), Visual Analogue Scale (VAS) for pain evaluation and Healing index (HI). The data collected was statistically evaluated. Results: On intergroup comparison, there was no statistical difference in the score from baseline (p>0.05); however, a statistically significant difference was seen at the end of 1 year (p<0.05). Moreover, 57-60% of arches showed recurrence of pigmentation in the laser group whereas; only 12.7-17% recurrence was seen in the cryosurgery group at the end of the first year. Conclusion: Treatment of gingival hyperpigmentation with laser and cryosurgery shows a marked improvement of gingival pigmentation in both groups, but the cryosurgery depigmentation sites showed more sustainability.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Hyperpigmentation/surgery , Laser Therapy/methods , Gingival Diseases , Melanins , Visual Analog Scale
17.
Journal of Clinical Hepatology ; (12): 2421-2431, 2023.
Article in Chinese | WPRIM | ID: wpr-998310

ABSTRACT

ObjectiveTo systematically review the efficacy and safety of laparoscopic choledochoscopy combined with holmium laser lithotripsy through a meta-analysis. MethodsThis study was conducted based on PRISMA guidelines, with a PROSPERO registration number of CRD42023406221. Chinese databases including CNKI, Wanfang Data, and VIP and foreign language databases such as PubMed, Embase, the Cochrane Library, and Web of Science were searched for original articles on traditional laparotomy versus laparoscopic choledochoscopy combined with holmium laser lithotripsy in the treatment of bile duct stones. Dichotomous variables were assessed by odds ratio (OR) and 95% confidence interval (CI), while continuous variables were assessed by weighted mean difference (WMD) and 95%CI, and a sensitivity analysis was performed for outcome measures with relatively high heterogeneity. The Begg test and Egger test were used to evaluate publication bias. Stata 15.0 and Review Manager 5.3 were used to perform the statistical analysis. ResultsA total of 26 retrospective studies from China were included in this study, with 2 238 patients in total. The meta-analysis showed that compared with traditional laparotomy for the treatment of bile duct stones, laparoscopic choledochoscopy combined with holmium laser lithotripsy had significantly shorter time of operation (WMD=-1.26, 95%CI: -1.36 to -1.16, P<0.001), length of hospital stay (WMD=-1.93, 95%CI: -2.64 to -1.12, P <0.001), and time to bowel function recovery (WMD=-1.52, 95%CI: -1.68 to -1.35, P<0.001), significantly less intraoperative blood loss (WMD=-1.79, 95%CI: -1.93 to -1.66, P<0.001), a significantly lower rate of intraoperative residual stone (OR=0.15, 95%CI: 0.11-0.20, P<0.001), and significantly fewer complications (OR=0.17, 95%CI: 0.13-0.23, P<0.001). ConclusionCompared with traditional laparotomy, laparoscopic choledochoscopy combined with holmium laser lithotripsy shows better efficacy in the treatment of bile duct stones.

18.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6): 50-53, 2023.
Article in Chinese | WPRIM | ID: wpr-995902

ABSTRACT

Objective:To observe the efficacy and adverse reactions of fractional radiofrequency (FRF) in the treatment of facial acne scars.Methods:Fifty-seven patients with facial acne depressed scars were enrolled with the nature of Dreno scars as the diagnostic criteria. They were treated with lattice radiofrequency. The treatment heads were arranged in a matrix with a treatment area of 1.2 cm ×1.2 cm, an energy density of 80-100 mJ/pin, and an interval of five-seven once a week. And they were followed up and evaluated for the clinical efficacy and adverse reactions 6 months after the last treatment. Scoring was carried out according to the ECCA weight scores, and the efficacy judged according to complete improvement, significant improvement, moderate improvement, and mild improvement.Results:After 3 times of fractional radiofrequency treatment of 57 patients, the effective rate was 44 cases, accounting for 77.2%; the ECCA weight scores before and after treatment were 65.9±25.0 and 47.7±20.2, respectively; the difference was statistically significant ( t=13.92, P<0.001); At the same time of improvement, 32 cases of patients' complexion, fineness of pores, and skin elasticity had been improved to varying degrees, and patient satisfaction was high. Adverse reactions were mainly mild burning sensation, erythema and edema, and some patients had pale yellow exudate, etc, which could be relieved in 5-7 days. Conclusions:Fractional radiofrequency treatment of facial acne scars is safe and effective, with short recovery period, few adverse reactions and high patient satisfaction.

19.
Chinese Journal of Dermatology ; (12): 468-470, 2023.
Article in Chinese | WPRIM | ID: wpr-994490

ABSTRACT

Rosacea is a chronic inflammatory dermatosis mostly occurring on the central face, and its pathogenesis is still unclear. Currently, drug treatment is the first-line therapy for rosacea. In recent years, photoelectric therapy has showed a favorable therapeutic effect on rosacea by selective photothermolysis. This review summarizes latest advances in photoelectric therapy for rosacea.

20.
Surg. cosmet. dermatol. (Impr.) ; 15: e20230111, 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1438327

ABSTRACT

Introdução: rugas e flacidez na região periorbital são queixas frequentes. O laser fracionado ablativo (LFA) CO2 10600nm e o Erbium: YAG 2940nm têm a capacidade de induzir a neocolagênese e a contração das fibras de colágeno. Objetivos: o objetivo do nosso estudo foi observar a eficácia de uma única sessão de laser fracionado Erbium: YAG 2940nm dual mode no tratamento de flacidez, rítides e bolsas de gordura das pálpebras superiores e inferiores. Métodos: 17 pacientes com flacidez, rítides e bolsas de gordura das pálpebras superiores e inferiores foram submetidos a uma sessão de laser fracionado ablativo Erbium: YAG 2940nm da plataforma Etherea em modo duplo. Os registros fotográficos foram realizados no mesmo ambiente antes do tratamento e um mês após o término do protocolo. A avaliação foi realizada objetivamente por cinco dermatologistas e cirurgiões plásticos independentes ao estudo. Resultados: as melhorias na avaliação de rítides, linhas de expressão e flacidez foram clínica e estatisticamente significativas, com poucos efeitos adversos, como edema, eritema e descamação. No entanto, as bolsas de gordura não melhoraram significativamente. Conclusão: uma única sessão com o modo duplo LFA Erbium: YAG 2940nm pode contribuir para uma melhoria significativa de rítides, linhas finas e flacidez da área periorbital.


Background: Wrinkles and flaccidity in the periocular region are frequent complaints. Ablative fractional lasers (AFL) CO2 10600nm and Erbium:YAG 2940nm can induce neocollagenesis and contraction of collagen fibers. Objective: Our study aimed to observe the effectiveness of one session of dual mode Erbium:YAG 2940nm fractional laser to treat sagging, rhytids, and fat bags of the upper and lower eyelids. Methods: Seventeen patients with sagging, rhytids, and fat bags of the upper and lower eyelids underwent one session of Ablative fractional laser (AFL) 2940nm from the Etherea platform in dual mode. Photographic records were taken in the same environment before treatment and one month after the end of the protocol, and five dermatologists and plastic surgeons independent of the study assessed them objectively. Results: The improvements in the evaluation of rhytids, fine lines, and flaccidity were clinically and statistically significant with few adverse events such as edema, erythema, and desquamation. However, eyelid bags did not improve significantly. Conclusion: A single session with the dual mode AFL Erbium:YAG tip 2940 can contribute to a significant improvement in rhytids, fine lines, and flaccidity of the periorbital area.

SELECTION OF CITATIONS
SEARCH DETAIL